Building systems › Partitions

Partitions

Interior and separating walls: single frame, double board, H studs or twin frame.

side A48 mmside B74 mm

Single-board partition 48

BA13 | 48 (LV50) | BA13

Typical use: Interior layout in housing, offices and retail.

Build-up
Side APlaco BA 13 (standard)
Side BPlaco BA 13 (standard)
Framing48 mm track and studs at 600 mm centres
InsulationIsover Drywall 50 mm (glass wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 74 mm
side A70 mmside B100 mm

Single-board partition 70 · 15 mm board

BA15 | 70 (LR60) | BA15

Typical use: Greater heights and stiffness, e.g. in public buildings.

Build-up
Side APlaco BA 15 (standard)
Side BPlaco BA 15 (standard)
Framing70 mm track and studs at 600 mm centres
InsulationRockwool Sonorock 60 mm (rock wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 100 mm
side A48 mmside B100 mm

Double-board partition 48

BA13+BA13 | 48 (LV50) | BA13+BA13

Typical use: Separating walls between dwellings, classrooms or offices. Higher sound insulation.

Build-up
Side A2 × Placo BA 13 (standard)
Side B2 × Placo BA 13 (standard)
Framing48 mm track and studs at 600 mm centres
InsulationIsover Drywall 50 mm (glass wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 100 mm
side A70 mmside B122 mm

Double-board partition 70

BA13+BA13 | 70 (LR60) | BA13+BA13

Typical use: Separating walls between dwellings, classrooms or offices. Higher sound insulation.

Build-up
Side A2 × Placo BA 13 (standard)
Side B2 × Placo BA 13 (standard)
Framing70 mm track and studs at 600 mm centres
InsulationRockwool Sonorock 60 mm (rock wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 122 mm
side A70 mmside B96 mm

Wet-area partition

H13 | 70 (LR60) | BA13

Typical use: Bathrooms, kitchens and wet rooms (moisture-resistant side facing the wet area).

Build-up
Side APlaco PPM 13 (moisture-resistant)
Side BPlaco BA 13 (standard)
Framing70 mm track and studs at 600 mm centres
InsulationRockwool Sonorock 60 mm (rock wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 96 mm
side A70 mmside B122 mm

Acoustic partition

BA13+A13 | 70 (LR60) | A13+BA13

Typical use: Hospitals, hotels, schools and noise-sensitive rooms.

Build-up
Side APlacophonique PPH 13 (acoustic) + Placo BA 13 (standard)
Side BPlacophonique PPH 13 (acoustic) + Placo BA 13 (standard)
Framing70 mm track and studs at 600 mm centres
InsulationRockwool Sonorock 60 mm (rock wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 122 mm
side A48 mmside B100 mm

Partition with H studs

BA13+BA13 | 48 H (LV50) | BA13+BA13

Typical use: Greater heights and stiffness, e.g. in public buildings.

Build-up
Side A2 × Placo BA 13 (standard)
Side B2 × Placo BA 13 (standard)
Framing48 mm track, back-to-back (H) studs at 600 mm
InsulationIsover Drywall 50 mm (glass wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 100 mm
side A48 mm48 mmside B148 mm

Twin-frame partition

BA13+BA13 | 48+48 (LV50+LV50) | BA13+BA13

Typical use: Between different uses or for the highest acoustic demand; allows services in the cavity.

Build-up
Side A2 × Placo BA 13 (standard)
Side B2 × Placo BA 13 (standard)
FramingTwin 48 mm stud frames, independent
Insulation2 × Isover Drywall 50 mm (glass wool)
AccessoriesJoint compound and tape, self-drilling screws, anchors and perimeter sealing strip.
Total thickness: 148 mm

Indicative section drawings. Final build-up, stud spacing and maximum height are adjusted to each project and to the manufacturer’s documentation.

Attach your drawings or bills of quantitiesTechnical quotation within 72 hours (PDF, BC3 or Excel).